<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-01 19-34-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 56 dBuV YLESUOMI
Pilot RDS Phase Difference
7.1 kHz 3.8 kHz 73 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19180 4,2753
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 3,40 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 1 (News) 1 0 1 1 19:34, 1.05.2026
RT
-
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6205, 6201, 6202, 6207
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 4,2753 Acquired: 2026/05/01 19.33.40 Total samples: 19180 Equivalent time: 0:15:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500 2000
FM Scope MAX: 6,0 dBr MIN: 2,3 dBr AVE: 3,40 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2026/05/01 19.33.40) 19.20 19.22 19.24 19.26 19.28 19.30 19.32 0 2 4 6 Pm [dBr]